Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
Braz. dent. sci ; 26(3): 1-6, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1509829

ABSTRACT

Objective: Teeth play a crucial role in masticatory efficiency and esthetic harmony making rehabilitation of partially edentulous patients a challenge because of the limitations of conventional removable partial dentures. As a therapeutic alternative, thermoplastic polymers are used in current dental practice either for practical processing purposes or aesthetics. However, it is recognized that the bond between acrylic resin artificial teeth and thermoplastic polymers has no chemical interaction, and depends on retentive features added to the teeth. This study analyzed the efficacy of two retentive forms of features through compressive strength test and as a secondary outcome, fracture and displacement resistance test. Material and Methods: Three groups of samples each with 14 sets of acrylic teeth were compared when two retentive features, single hole and groove retention, and a control group with teeth without any specific form. The experimental unit consisted of six maxillary anterior teeth, positioned in a linear pattern into a polypropylene block, where each tooth was submitted to a static load until its removal, on a universal testing machine. Results: Those specimens with a groove retention presented larger resistance to displacement when compared to the other groups (p <0.05). This was emphasized by the fracture of the tooth tested, with part of the cervical portion remaining embed in the base, and not its displacement as with (or without) the retentive feature. Conclusion: In this study, the type of retention influenced significantly to a better retention considering teeth and thermoplastic polymer base. The data in this study indicates that a groove placed on the artificial tooth offers significantly better retention efficacy to the point where the displacement was only possible after its fracture (AU)


Objetivo: Os dentes são um fator essencial na eficiência mastigatória. A harmonia estética e a reabilitação dos indivíduos parcialmente dentados tornam-se um desafio, frente às limitações das próteses parciais removíveis convencionais. Como uma alternativa terapêutica, os polímeros termoplásticos são utilizados na odontologia contemporânea, tanto para o seu processamento prático como seu apelo estético. Entretanto, pouco se sabe a respeito da união entre a resina acrílica de dentes artificiais e resinas termoplásticas, assim como a influência dos mecanismos de retenção, uma vez que não há interação química entre eles. O objetivo deste estudo foi analisar duas formas de retenção de dentes de resina acrílica a bases de prótese de material termoplástico, por força compressiva e como desfecho secundário, teste de resistência a fratura e deslocamento dos dentes artificiais. Material e Métodos: O presente estudo analisou dois tipos diferentes de retenções: uma cavidade com único ponto e uma canaleta de mesial a distal; e como grupo controle, dentes colocados sem qualquer recurso específico. A unidade experimental consistiu de seis dentes superiores anteriores, posicionados em linha em um bloco de polipropileno. Em cada dente artificial foi aplicada força até a sua remoção, em uma máquina universal de ensaios. Resultados: Os resultados mostraram que a retenção com canaleta apresentou maior força de deslocamento, quando comparado com os outros grupos (p <0,05). Tal fato foi evidenciado pelo teste de fratura e deslocamento, no qual parte da porção cervical do dente artificial permaneceu unida à base, não ocorrendo o deslocamento com (ou sem) a retenção. Conclusão: Neste estudo, o tipo de retenção influenciou de forma significante a retenção de dentes artificiais de resina acrílica a bases de prótese termoplásticas. Os dados deste estudo indicam que a confecção da retenção em canaleta nos dentes artificiais oferece significante aumento na eficiência da retenção, ao ponto em que o deslocamento do dente ocorreu somente após sua fratura (AU).


Subject(s)
Polypropylenes , Tooth, Artificial , Acrylic Resins , Dentures
2.
Article | IMSEAR | ID: sea-222423

ABSTRACT

Context: Artificial teeth are widely used in oral rehabilitation. Despite the benefits, they are more susceptible to colour changes, causing aesthetic problems. Aims: To evaluate the effect of conventional cigarette and straw smoke on the colour of artificial teeth and the effectiveness of hygiene protocols in removing pigmentation. Material and Methods: Acrylic resin incisors were divided into two groups (n = 50): Exposed to conventional cigarette and straw smoke. Regarding the effectiveness of hygiene protocols, the teeth were divided into ten subgroups with predetermined immersion times. The colour was measured with a colorimeter. The CIE values L* a* b* were recorded before and after exposure to smoke and after hygiene protocols. Statistical analysis used T?test of independent samples and two?way ANOVA with Bonferroni post?test (? = 0.05). Results: Conventional (16.16 ± 1.65) and straw (16.29 ± 1.95) cigarettes provided clinically unacceptable ?E values, with no significant difference between them (P = 0.719). Conventional cigarettes promoted less luminosity (?L = –12.68 ± 1.28) (P < 0.001) and straw greater tendency to yellow (?b = 11.00 ± 1.46) (P < 0.001). The hygiene protocols influenced the ?E, ?L, and ?b of the samples, depending on the type of smoke (P < 0.05). Conclusions: The conventional and rolled cigarette smoke promote an unacceptable colour change in artificial teeth. Hygiene protocols with the use of brushing, in isolation or in association with chemical solutions are more effective in removing pigmentation caused by both types of cigarettes compared to only the chemical solution

3.
Rev. odontol. UNESP (Online) ; 50: e20210031, 2021. ilus
Article in English | LILACS, BBO | ID: biblio-1352131

ABSTRACT

Introduction Dental practice professionals encounter several urgency cases, mainly related to endodontic problems. To attend to these, professionals need extensive prior preclinical training, being one of the main difficulties the search for models that simulate dental morphology. Aim To compare the external morphometry of multirooted artificial teeth to literature. Material and method The artificial teeth (Upper First Premolar, Upper First Molar and Lower First Molar) were donated by the manufacturers: Fábrica de Sorrisos (FS) and IM do Brasil LTDA (IM), totaling 30 teeth. The total length of the tooth and root, height and buccal-palatal and mesial-distal dimensions of the crown were measured with a digital pachymeter. The data were placed in a spreadsheet and the statistical analysis was performed [ANOVA or Kruskal-Wallis and then, Dunnett's test (α=5%)]. Result The Upper Molar samples of the company Fábrica de Sorrisos presented all variables within the morphometric patterns described in the literature. The other dental groups presented statistically significant differences, maintaining or not a certain proportionality. Conclusion Of all the dental groups analyzed, the upper molar from the company Fábrica de Sorrisos was the only one that presented all the external morphometric aspects according to literature.


Introdução Dentro da prática odontológica, os profissionais podem receber diversos casos de urgência, principalmente relacionados a problemas endodônticos e, para atendê-los, há a necessidade de um extenso treinamento pré-clínico prévio, sendo uma das principais dificuldades a busca por modelos que simulem a morfologia dentária. Objetivo Comparar a morfometria de dentes artificiais polirradiculares à literatura. Material e método Os dentes artificiais (Primeiro Pré-molar Superior, Primeiro Molar Superior e Primeiro Molar Inferior) foram doados pelos fabricantes: Fábrica de Sorrisos (FS) e IM do Brasil Ltda. (IM), totalizando 30 dentes. Foi realizada mensuração do comprimento total do dente e o da raiz, da altura e das dimensões vestíbulo-palatina e mésio-distal da coroa, com paquímetro digital. Os dados foram dispostos em uma planilha de cálculo e realizou-se a análise estatística [ANOVA ou Kruskal-Wallis e, após, teste de Dunnett (α=5%)]. Resultado A amostra de molares superiores da empresa FS apresentou todas as variáveis dentro dos padrões morfométricos descritos na literatura. Os demais grupos dentários apresentaram diferenças estatisticamente significantes, mantendo ou não certa proporcionalidade. Conclusão De todos os grupos dentários pesquisados o molar superior da empresa FS foi o único que apresentou todos os aspectos morfométricos externos de acordo com os dados da literatura.


Subject(s)
Reference Standards , Tooth, Artificial , Analysis of Variance , Endodontics , Literature , Molar , Tooth/anatomy & histology
4.
Int. j. odontostomatol. (Print) ; 14(4): 648-652, dic. 2020. graf
Article in English | LILACS | ID: biblio-1134552

ABSTRACT

ABSTRACT: Prosthodontics, in general, aims to rehabilitate the masticatory function of the patient, as well as the stomatognathic system, maintaining his or her individual facial characteristics. The immediate removable complete denture is placed immediately after extraction of the natural teeth and allows adaptation of the patient from the dentate state to the denture, until the definitive denture is placed. When an immediate complete denture is fabricated, esthetics plays a fundamental role and thus the assembly of artificial teeth can be performed maintaining the same position, alignment and arrangement of the remaining anterior teeth, providing a natural and esthetic appearance to the denture, thus the transition from the dentate to the edentulous state is less noticeable. This paper reports the case of a patient who needed oral rehabilitation with an immediate upper complete denture and presented favorable smile esthetics of the anterior teeth, which allowed the preservation of alignment, position and arrangement of natural teeth during the assembly of artificial teeth, maintaining and preserving the esthetic individuality and facial harmonization, meeting the patient's desire and expectations.


RESUMEN: La prostodoncia, en general, tiene como objetivo rehabilitar la función masticatoria del paciente, así como el sistema estomatognático, manteniendo sus características faciales individuales. La dentadura postiza completa removible se coloca inmediatamente después de la extracción de los dientes naturales y permite la adaptación del paciente del estado dentado a la dentadura, hasta que se coloque la dentadura definitiva. Cuando se fabrica una dentadura postiza completa inmediata, la estética juega un papel fundamental y, por lo tanto, el ensamblaje de dientes artificiales se puede realizar manteniendo la misma posición, alineación y disposición de los dientes anteriores restantes, proporcionando un aspecto natural y estético a la dentadura, por lo tanto, la transición desde el estado dentado hasta el estado desdentado es menos notable. Este artículo informa el caso de una paciente que necesitó rehabilitación oral con una dentadura postiza completa superior inmediata y presentó una estética de sonrisa favorable de los dientes anteriores, lo que permitió preservar la alineación, la posición y la disposición de los dientes naturales durante el ensamblaje de los dientes artificiales, manteniendo y preservando la individualidad estética y la armonización facial, satisfaciendo los deseos y expectativas del paciente.


Subject(s)
Humans , Female , Middle Aged , Denture, Complete, Immediate , Denture, Complete, Upper , Radiography, Dental/methods , Esthetics, Dental
5.
Rev. odontol. UNESP (Online) ; 48: e20190053, 2019. tab, graf, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1043178

ABSTRACT

Resumo Introdução Dentes artificiais têm sido utilizados para a prática odontológica e, segundo seus fabricantes, apresentam muita similaridade aos dentes humanos para treinamento. Objetivo Avaliar a radiopacidade de dentes endodônticos artificiais para uso em atividades de ensino e saber a percepção de docentes quanto à análise radiográfica. Material e método Trinta réplicas de incisivos centrais superiores de três marcas comerciais (Fábrica de Sorrisos, IM do Brasil e Real Dent) e um incisivo humano foram utilizados. Foram dispostos sobre um sensor radiográfico o dente humano e um dente artificial de cada empresa. As análises de radiopacidade foram feitas no programa Photoshop® em triplicata em quatro regiões distintas: porção central da coroa e nos terços cervical, médio e apical do canal. A percepção quanto à utilização dos dentes como instrumento prático de ensino foi avaliada por meio de um questionário aplicado a oito professores de endodontia. Para análise estatística dos valores de radiopacidade, foi utilizada a ANOVA, seguida do teste de Tukey. Foi empregado um nível de significância de 5%. Para análise do questionário, foram empregados métodos descritivos e por porcentagem de dados no que se refere à frequência das respostas. Resultado Houve diferença de radiopacidade entre os diferentes dentes testados em cada região analisada (p > 0,05). Na percepção dos professores com relação à utilização dos dentes no ensino, eles colocaram em ordem crescente os seguintes dentes para uso: IM do Brasil, Fábrica de Sorrisos, Real Dent e humano. Conclusão A radiopacidade dos dentes artificiais foi diferente do humano. O dente artificial da Fábrica de Sorrisos apresentou os maiores valores de radiopacidade. Contudo, os professores consideraram ideais para utilização no ensino apenas o dente humano e o dente da Real Dent.


Abstract Introduction Artificial teeth have been used for dental practice which, acoording to their manufactures, bear much similarity to human teeth for training. Objective To evaluate radiopacity of artificial endodontic teeth for use in teaching activities and to know the perception of teachers regarding radiographic analysis. Material and method Thirty replicates of upper central incisors of three trade marks (Fábrica de Sorrisos, IM do Brasil and Real Dent) and a human incisor were used. On a radiographic sensor, human tooth and one artificial tooth of each marks were arranged. Radiopacity analyzes were performed using Photoshop® in triplicate in four distinct regions: central portion of the crown and in the cervical, middle and apical thirds of the canal. The perception about the use of teeth as a practical teaching instrument was evaluated through a questionnaire applied to eight teachers of Endodontics. For statistical analysis of the radiopacity values ​​ANOVA was used, followed by the Tukey test. Significance level of 5%. For the analysis of the questionnaire were used descriptive methods and percentage of data regarding the frequency of responses. Result There was a difference in radiopacity between the different teeth tested, in each region analyzed (P > 0.05). In the teachers' perception regarding the use of teeth in teaching, the teachers placed the following teeth for use: IM do Brasil, Fábrica de Sorrisos, Real Dent and human. Conclusion The radiopacity of the artificial teeth was different from the human teeth. The artificial tooth of the Fábrica de Sorrisos presented the highest values ​​of radiopacity. The teachers considered ideal for use in teaching only the human teeth and the prototype Real Dent.


Subject(s)
Tooth, Artificial , X-Rays , Education, Dental , Endodontics , Tooth , Surveys and Questionnaires
6.
Rev. odontol. UNESP (Online) ; 48: e20190052, 2019. tab, graf
Article in Portuguese | LILACS, BBO | ID: biblio-1043172

ABSTRACT

Resumo Introdução Dentes artificiais têm sido empregados para a prática de ensino pré-clínico. Porém, não se sabe o comportamento dos mesmos frente aos diferentes procedimentos realizados durante um tratamento endodôntico simulado. Objetivo Avaliar a microdureza de réplicas de dentes humanos, frente a diferentes soluções irrigadoras. Material e método Quarenta e cinco incisivos centrais superiores artificiais de três marcas comerciais nacionais (dentes "A", "B" e "C") e 15 incisivos humanos foram utilizados. As amostras foram seccionadas a 5 mm do ápice dentário. Os fragmentos radiculares foram fixados em resina para posterior teste de microdureza. Os ensaios da microdureza Knoop foram realizados em dois momentos: momento 1 - microdureza inicial; momento 2 - microdureza final, que foi feita após o uso das soluções irrigadoras (Cloreto de Sódio a 0,9%, Hipoclorito de Sódio a 2,5% e Gluconato de Clorexidina a 2%). As endentações deixadas na superfície da amostra foram mensuradas. O valor obtido para microdureza de cada amostra foi feita com base na média de três endentações. Para análise estatística, foram utilizados os testes ANOVA e Teste t pareado, com nível de significância de 5%. Resultado Os dentes artificiais "A" e "C" apresentaram valores inferiores de microdureza quando comparados ao dente humano (P = 0,05). Não houve diferença estatística entre os dentes artificiais "B" e o dente humano (P = 0,2428). Quanto ao uso das diferentes soluções irrigadoras, também não houve diferença na microdureza das peças dentárias. Conclusão Embora a solução irrigadora não tenha influenciado a microdureza, os dentes artificiais apresentaram valores de dureza inferiores aos do dente humano.


Abstract Introduction Artificial teeth have been used for preclinical teaching practice. However, the behavior of the same is not known in relation to the different procedures performed during a simulated endodontic treatment. Objective To evaluate the microhardness of replicates of human teeth, in front of different irrigating solutions. Material and method Forty-five artificial upper central incisors of three national trade marks (teeth "A", "B" and "C") and fifteen human incisors were used. Samples were sectioned 5 mm from the apex. The root fragments were fixed in resin for later microhardness test. The Knoop microhardness tests were performed in two moments: moment 1 - initial microhardness; moment 2 - final microhardness, which was done after the use of the irrigating solutions (0.9% sodium chloride, 2.5% sodium hypochlorite and 2% chlorhexidine gluconate). The indentations left on the sample surface were measured. The obtained value for microhardness of each sample was made based on the average of three indentations. ANOVA and Paired t-test were used for statistical analysis. Significance level of 5%. Result Artificial teeth "A" and "C" presented lower values ​​of microhardness when compared to human teeth (P = 0.05). There was no statistical difference between the artificial teeth "B" for the human (P = 0.2428). Regarding the use of different irrigation solutions, there was also no difference in the microhardness of dental pieces. Conclusion Although the irrigating solution did not influence the microhardness, the artificial teeth presented values ​​of hardness inferior to the human tooth.


Subject(s)
Sodium Hypochlorite , Tooth, Artificial , Sodium Chloride , Chlorhexidine , Hardness Tests , Education, Dental , Endodontics
7.
Rev. Salusvita (Online) ; 37(4): 839-853, 2018.
Article in Portuguese | LILACS | ID: biblio-1050804

ABSTRACT

Introdução: apesar dos avanços tecnológicos, os materiais restauradores estão expostos ao meio bucal onde há comumente a ingestão de certos alimentos e bebidas com substâncias corantes, as quais tendem, no decorrer do tempo, causar alterações de cor nos dentes naturais, materiais restauradores e, inclusive, nos dentes artificiais utilizados para a confecção das próteses dentárias. Objetivo: avaliar in vitro o manchamento de duas marcas de dentes artificiais quando imersos em soluções corantes. Métodos: para a confecção dos 40 corpos de prova (CP), sendo 20 dentes Biotone® e 20 dentes Biolux®, utilizou-se uma broca MINICUT para desgaste dos dentes e obtenção de amostras com uma espessura padrão de 2 mm e discos de lixa d'água SOF-LEX (3M) de granulação decrescente para dar o acaba mento superficial. Os CP foram divididos em 4 grupos de estudo: G1- foram imersos no café; G2- imersos no vinho tinto; G3- imersos no urucum; e G4- na água destilada (controle). Diariamente os CP permaneceram imersos por um período de 4 horas; em seguida, foram retirados, lavados em água corrente, secos em papel absorvente, imersos em recipiente com água destilada e armazenados em estufa biológica a 37°C, nas horas subseqüentes, por 21 dias. A avaliação do manchamento foi feita nos períodos inicial (0), 7, 14 e 21 dias de imersão, através de análise computadorizada (Adobe Photoshop 7.0). Resultados e discussão: os resultados apontaram que as amostras que ficaram imersas em urucum sofreram as maiores variações, pigmentando-se desde os primeiros dias do experimento; sendo seguido pelos CP imersos em café e vinho tinto que apresentaram nível de significância semelhante quanto à alteração de cor e fator tempo. Conclusão: conclui-se que houve maior intensidade de manchamento das amostras do grupo urucum, e que a alteração de cor aumentou progressivamente em função do tempo para as duas marcas testadas.


Introduction: despite technological advances, restorative materials are exposed to the oral environment where there is a common ingestion of certain foods and beverages with coloring substances, which in the course of time tend to cause color changes in natural teeth, restorative materials and even on the artificial teeth used to make dental prostheses. Aim: to evaluate in vitro the staining of two artificial tooth marks when immersed in dye solutions. Methods: For the preparation of the 40 test specimens (CP), 20 Biotone® teeth and 20 Biolux® teeth, a MINICUT bit for tooth wear was used and samples with a standard thickness of 2 mm

Subject(s)
Dental Prosthesis , Tooth Bleaching , Coloring Agents
8.
Dental press j. orthod. (Impr.) ; 22(4): 47-52, July-Aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-891086

ABSTRACT

ABSTRACT Objective: The aim of this in vitro study was to evaluate and compare the effects of grinding, drilling, sandblasting, and ageing prefabricated teeth (PfT) on the shear bond strength (SBS) of orthodontic brackets, as well as the effects of surface treatments on the adhesive remnant index (ARI). Methods: One-hundred-ninety-two PfT were divided into four groups (n = 48): Group 1, no surface treatment was done; Group 2, grinding was performed with a cylindrical diamond bur; Group 3, two drillings were done with a spherical diamond bur; Group 4, sandblasting was performed with 50-µm aluminum oxide. Before the experiment, half of the samples stayed immersed in distilled water at 37oC for 90 days. Brackets were bonded with Transbond XT and shear strength tests were carried out using a universal testing machine. SBS were compared by surface treatment and by ageing with two-way ANOVA, followed by Tukey's test. ARI scores were compared between surface treatments with Kruskal-Wallis test followed by Dunn's test. Results: Surface treatments on PfT enhanced SBS of brackets (p< 0.01), result not observed with ageing (p= 0.45). Groups II, III, and IV showed higher SBS and greater ARI than the Group 1 (p< 0.05). SBS was greater in the groups 3 and 4 (drilling, sandblasting) than in the Group 2 (grinding) (p< 0.05). SBS and ARI showed a positive correlation (Spearman's R2= 0.57; p< 0.05). Conclusion: Surface treatment on PfT enhanced SBS of brackets, however ageing did not show any relevance. Sandblasting and drilling showed greater SBS than grinding. There was a positive correlation between SBS and ARI.


RESUMO Objetivo: o objetivo desse estudo in vitro foi avaliar e comparar os efeitos de desgastes, perfurações, jateamento e envelhecimento de dentes pré-fabricados (Dpf) na resistência ao cisalhamento (RC) de braquetes ortodônticos, bem como os efeitos dos tratamentos de superfície no índice de adesivo remanescente (ARI). Métodos: 192 Dpf foram divididos em quatro grupos (n = 48): Grupo 1, sem tratamento; Grupo 2, desgaste de sulcos com broca diamantada cilíndrica; Grupo 3, duas perfurações com broca diamantada esférica; e Grupo 4, jateamento com partículas de óxido de alumínio de 50µm. Antes do experimento, metade das amostras ficou imersa em água destilada a 37oC durante 90 dias. Os braquetes foram colados com Transbond XT e os testes de cisalhamento foram realizados com uma máquina universal de ensaios. A RC foi comparada, por tratamento de superfície e por envelhecimento, utilizando-se análise de variância e teste de Tukey. Os escores ARI foram comparados entre os tratamentos de superfície usando o teste Kruskal-Wallis e o teste de Dunn. Resultados: os tratamentos de superfície aumentaram a RC dos braquetes (p < 0,01) e o envelhecimento não aumentou a RC (p = 0,45). Os Grupos 2, 3 e 4 mostraram maior RC e maior ARI do que o Grupo 1 (p < 0,05). A RC foi maior nos Grupos 3 e 4 (perfuração, jateamento) do que no Grupo 2 (desgaste) (p < 0,05). RC e ARI apresentaram correlação positiva (R2 = 0,57; p < 0,05). Conclusão: o tratamento de superfície dos Dpf aumentou a RC dos braquetes; porém, o envelhecimento não foi relevante. O jateamento e a perfuração mostraram maior RC do que o desgaste. Existe uma correlação positiva entre RC e ARI.


Subject(s)
Tooth, Artificial , Orthodontic Brackets , Surface Properties , Materials Testing , Dental Bonding , Shear Strength , Dental Stress Analysis
9.
Journal of Practical Stomatology ; (6): 27-30, 2017.
Article in Chinese | WPRIM | ID: wpr-619226

ABSTRACT

Objective:To evaluate the effects of different denture cleaners on the discoloration of heat-cured denture base resin and artificial teeth.Methods:40 same specifications of the heat-curing denture base resin and 40 artificial central incisors were immerced in an acombination stain of coffee,tea and soy sauce for 4 weeks.Then specimens and artificial teeth were randomly distributed into 4 groups and soaked in Polident,Steradent,0.5% sodium hypochlorite solution and distilled water for 4 hours respectivelly(n =10).Color differences(△E) were measured by using a colorimeter and a denture spectrophotometer before and after staining,and after cleaning.Results:Before or after staining there was no difference of △E among the groups of denture base risn or artificial teeth(P > 0.05).After cleaning the denture base resin and the artificial teeth in the group of 0.5% sodium hypochlorite solution presented higher △E than the other groups(P < 0.05),in group of distilled water presented lower △E than the other groups(P < 0.05).No significant difference was found between Polident group and Steradent group(P >0.05).The △E of the denture base resin and artificial teeth.in distilled water group before staining and after cleaning were the highest among the groups(P <0.05).Conclusion:0.5% sodium hypochlorite solution,Polident and Steradent are effective in removing the discoloration from the heat-cured acrylic resin and artificial teeth.0.5% sodium hypochlorite solution is the most effective,Polident and Steradent are the similar.

10.
The Journal of Korean Academy of Prosthodontics ; : 394-402, 2017.
Article in Korean | WPRIM | ID: wpr-91594

ABSTRACT

PURPOSE: The purpose of this study is to evaluate the displacement of artificial tooth of monolithic complete denture manufactured by milling and 3D printing method in which the denture base and the artificial teeth are simultaneously made. MATERIALS AND METHODS: Twelve upper and lower complete dentures for each were made by milling and 3D printing method. Group Up and Group Lp are a group of upper and lower dentures made by printing, and Group Um and Group Lm are denture groups made by milling. Group Uc and Group Lc are is a group of finally designed upper and lower dentures respectively. Measurements were performed between both central incisors (AB, ab), both canines (CD, cd), both first molars (EF, ef), between an incisor and a first molar (AE, ae), and between incisor and lingual point (AG, ag) for each upper and lower denture. RESULTS: AG and ag value between printed dentures and original ones as well as between milled dentures and original ones showed a statistically significant difference (One-way ANOVA, P<.05) in both lower and upper monolithic dentures. In the lower monolithic ones, ab, cd and ef value revealed a significant difference between Group Lp and Group Lm (One-way ANOVA, P<.05). CONCLUSION: Dentures made using milling or 3D printers revealed statistically significant difference compared with those of original data. However, it showed clinically very accurate reproducibility.


Subject(s)
Denture Bases , Denture, Complete , Dentures , Incisor , Methods , Molar , Printing, Three-Dimensional , Tooth, Artificial
11.
Journal of Practical Stomatology ; (6): 32-36, 2016.
Article in Chinese | WPRIM | ID: wpr-486006

ABSTRACT

Objective:To evaluate the staining of different resin artificial teeth treated by different coloring agents.Methods:1 6 teeth of each brand of Endura Anterio,Heraeus's three color synthetic resin teeth,synthetic resin teeth,Efucera-A,KaiFeng synthetic resin teeth were respectively made into test specimens.A surface roughness tester was used to measure Ra along 3 tracks on each sur-face.The specimens of the same brand were respectively immersed into coffee,tea and vinegar as the test groups and distilled water as a control for 4 weeks.The initial and further color of each specimen was measured using a colorimeter.The CIE L* a* b* values were recorded and color differences (ΔE)after immersion were calculated.Data were statistically analyzed by ANOVA.Results:The color stability of the specimens in coffee and tea was significantly affected by the coloring agents(P 0.05).The ΔE values in the same coloring agent were as follows:Efucera-A,Heraeus's three color synthetic resin teeth,Endura Anterio,synthetic resin teeth and KaiFeng synthetic resin teeth (P <0.05).Conclusion:Extrinsic pigment can make resin artificial teeth stained,and the staining susceptibility of five resin artificial teeth is different.

12.
RGO (Porto Alegre) ; 63(3): 263-270, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-765062

ABSTRACT

Objective: To evaluate the Knoop hardness, composition, and wear resistance of acrylic-resin artificial teeth exposed to mechanical toothbrushing.Methods: Artificial teeth from three commercial brands - Biotone, Trilux, and Soluut PX - were used. From each brand, 10 teeth were selected for wear evaluation after mechanical brushing, 10 for microhardness testing, and 5 for composition analysis. Specimens underwent 55,000 brushing cycles, under a 200-g load and at a frequency of 250 cycles per minute, using a soft-bristled toothbrush (IndicatorPlus 30, Oral-B) soaked in a 1:1 toothpaste/water slurry (Oral B Pró Saúde). Microhardness testing was performed using a 25-g load for 15 seconds in an HMV-2 hardness tester (Shimadzu). The composition of teeth from different brands was determined by scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM/EDS) (Jeol JSM 5800).Results: Wear results after mechanical brushing were compared by means of the paired t-test, whereas those obtained in microhardness testing were compared by ANOVA with Bonferroni correction. There was no statistically significant difference between brands in either trial.Conclusion: Composition analysis revealed that all of the artificial teeth analyzed contain carbon and oxygen. Trilux and Soluut PX brand teeth also contain silicon; however, the presence of filler particles did not result in increased resistance.


Objetivo: Avaliar a microdureza Knoop, composição e resistência ao desgaste de dentes artificiais de resina acrílica submetidos ao ensaio de escovação mecânica.Métodos: Foram selecionados 10 dentes para o ensaio de escovação mecânica, 10 para microdureza e 5 para determinação da composição, de três marcas comerciais: Biotone, Trilux e Soluut PX. As amostras foram submetidas a 55.000 ciclos de escovação, sob carga de 200g e frequência de 250 ciclos por minuto, utilizando escova dental macia (IndicatorPlus 30, Oral-b), imersas em solução de dentifrício/água destilada na proporção de 1:1(Oral B Pró Saúde). O ensaio de microdureza foi realizado sob carga de 25 gramas durante 15 segundos em microdurômetro (HMV-2, Shimadzu). A composição das diferentes marcas comerciais foi determinada em MEV 5800, utilizando EDS que permite a análise química por meio de raios-x.Resultados: Os resultados obtidos no ensaio de escovação mecânica foram submetidos ao teste t pareado e aqueles obtidos no ensaio de microdureza Knoop foram submetidos à Análise de Variância e teste de BONFERRONI. Não houve diferença estatisticamente significativa entre as marcas em ambos os ensaios.Conclusão: A análise da composição revelou que todos os dentes artificiais possuem carbono e oxigênio. Os dentes das marcas Trilux e Soluut PX apresentam também silício em sua composição, entretanto, a presença de partículas de carga não resultou em aumento da resistência.

13.
Braz. dent. sci ; 17(2): 63-69, 2014. ilus, tab
Article in English | LILACS, BBO | ID: lil-728127

ABSTRACT

Objective: To evaluate the visual perception of dentistry professors, technicians and undergraduates on tooth color selection through varying the background contrast and tooth translucency. Material & Methods: Fifteen artificial teeth of different colors and translucencies were used and divided into three groups and placed onto cardboards in the following colors: white, red and black. Blindly, the observers (professors (n = 30), technicians (n = 30) and undergraduates (n = 30), selected the artificial tooth color that they judged compatible with VITA scale, when positioned onto the three background colors, at constant illumination through white artificial light. The obtained data were statistically analyzed by Kruskal-Wallis test. Results: There were no statistically significant differences among the studied populations in tooth color selection, regardless of the background colors, with all observers exhibiting a high number of errors. There were statistically significant differences in the number of matching answers among the studied teeth, with those exhibiting different translucencies showing the highest error rate (D1= 2 right answers; D4 = 0 right answers). Conclusion: Professional expertise was not decisive in tooth color selection; the number of matching answers of the three populations varied according to the background used; the most translucent teeth with different resin layers exhibited the smallest number of matching answers and the observers’ visual acuity differed and it should be effectively trained to achieve success in tooth color selection of prostheses and restorations


Objetivo: Avaliar a percepção visual na seleção de cor de dentes por professores de odontologia, técnicos de laboratório e alunos da graduação com contraste simultâneo de fundo. Material e Métodos: Foram utilizados 15 dentes de estoque de diferentes cores e translucidez, divididos em três grupos e posicionados em fundos de papel cartão nas cores: branco, vermelho e preto. Os observadores professores (n = 30), técnicos de laboratório (n = 30) e alunos (n = 30), selecionavam a cor dos dentes de estoque de diferentes cores, posicionados nas três cores de fundo, sempre com iluminação de luz artificial branca e comparavam com dentes da escala de cores. Após obtenção dos dados estes foram analisados pelo teste estatístico de Kruskal- Wallis. Resultados: os resultados mostraram que não existem diferenças estatisticamente significantes entre as populações estudadas, quando da seleção da cor dos dentes, independentemente das cores dos fundos e que o número de acertos foi muito pequeno, necessitando de melhor aprimoramento dos profissionais e alunos de graduação. Conclusão: Não houve diferença nos valores de acerto dos professores, alunos e técnicos de laboratório; a distribuição de acertos nos três diferentes fundos foi semelhante para os observadores; a porcentagem de erros entre os observadores foi muito elevada; a maior parte dos acertos diferiu conforme o dente avaliado, devido à maior translucidez e camadas de resina existentes e há necessidade de maior treinamento dos profissionais de odontologia para seleção das cores dos dentes.


Subject(s)
Spectrophotometers , Tooth, Artificial
14.
Int. j. odontostomatol. (Print) ; 7(1): 99-105, 2013. ilus, tab
Article in English | LILACS | ID: lil-690497

ABSTRACT

The aim of this study was to evaluate the shear bond strength between acrylic teeth and heat-activated acrylic denture base resin using five different disinfectants solutions after simple immersion or under ultrasonic cleaner action. A total of 144 acrylic denture resin specimens were produced with both types of acrylic denture tooth (Biolux® and Trilux®). The specimens were randomly divided into subgroups according to the disinfection procedure used (immersion in Listerine®, Cepacol®, Periogard®, Riozyme II® and Cloro Rio® 1%, and/or ultrasonic cleaning action). The shear bond strength between acrylic teeth and denture base was assessed using a universal testing machine and the data obtained were analyzed by means of ANOVA followed by Fisher's LSD Multiple-Comparison test. The two layers teeth presented a bond strength average of 3.43 MPa while the three layer ones had an average of 3.02 MPa. The association of ultrasonic cleaner and the disinfectant solutions studied did not affect negatively the teeth bond resistance to the denture base. The three layer acrylic teeth had a lower shear bond strength compared to those with double pressing when immersed in disinfection solutions, regardless of the ultrasonic cleaner use.


El objetivo de este estudio fue evaluar la resistencia al cizallamiento entre dientes de resina acrílica y bases acrílicas curadas mediante calor, junto al uso de cinco soluciones de desinfectantes diferentes, mediante inmersión simple o bajo ultrasonido. Un total de 144 bases de acrílico fueron confeccionadas con los dos tipos de dientes de resina (Biolux ® y Trilux ®). Los especímenes se dividieron aleatoriamente en subgrupos de acuerdo con el procedimiento de desinfección utilizado (inmersión en Listerine ®, Cepacol ®, Periogard ®, Riozyme II ® y Cloro Río ® 1%, y/o acción de limpieza por ultrasonido). Se evaluó la resistencia al cizallamiento entre los dientes de resina y la base de la prótesis utilizando una máquina de ensayo universal; los datos obtenidos se analizaron mediante ANOVA seguido por el test LSD de Fisher de comparaciones múltiples. Las dos capas de los dientes presentaron una fuerza de adherencia promedio de 3,43 MPa, mientras que las tres capas tenían un promedio de 3,02 MPa. La asociación de limpiador ultrasónico y las soluciones desinfectantes estudiados no afectaron negativamente la resistencia de los dientes a la base de la prótesis. Las tres capas de acrílico de los dientes tuvieron una resistencia al cizallamiento menor en comparación con aquellos con doble prensado cuando se sumergen en soluciones desinfectantes, independientemente del uso de limpiador ultrasónico.

15.
ImplantNews ; 10(5): 637-645, 2013. ilus
Article in Portuguese | LILACS, BBO | ID: lil-699628

ABSTRACT

Os dentes artificiais de próteses totais têm alto índice de descolamento e/ou fratura. Embora existam diversas técnicas para melhorar o nível de adesão do dente a base acrílica, é possível a utilização de retenções metálicas com esse fim, embora não existam estudos sobre a eficácia dessas retenções. Foi realizada uma análise, através do método de elementos finitos, de próteses totais fixas implantossuportadas, comparando a pressão trativa na superfície dos dentes artificias de próteses com retenções metálicas nos dentes ou na base da prótese, quando comparados com uma prótese sem nenhuma retenção adicional. A análise considerou diferentes padrões de carga mastigatória. Os resultados demonstraram que a confecção de retenções metálicas na infraestrutura da base diminuiu significativamente a pressão de descolamento sobre a superfície do dente artificial, entretanto, as retenções localizadas nos dentes foram mais eficientes na diminuição da pressão do que as retenções na base acrílica. Um caso clínico foi colocado para demonstrar a confecção das retenções. O estudo concluiu que a utilização de retenções metálicas é benéfica para diminuir a pressão trativa sobre os dentes artificiais, mas que a posição das retenções também é importante. Sempre que possível, essas devem ser confeccionadas internamente aos dentes artificiais.


Artificial teeth used for complete dentures have a high rate of detachment and/or fracture. Although there are several techniques to improve adhesion of acrylic tooth, it is possible to use metal retentions for this purpose, although no studies testing its effectiveness exist. A finite element method was used for a total fixed implant-supported prosthesis to investigate tension on the surface of artificial teeth, with metal retentions on the teeth or the acrylic base, compared with prosthesis without any additional retention. The analysis considered different patterns of masticatory load. It was demonstrated that the use of retentive features in the infra-structure significantly reduces the pressure on the surface of artificial teeth; however, retentions located inside the teeth were more efficient in reducing the pressure than retentions located in the acrylic base. A case study demonstrates the use of such retentions. The use of metal retention is beneficial to reduce tension on artificial teeth, but the position of the retention is also important. Whenever possible, they must be made internally to the artificial tooth.


Subject(s)
Denture, Complete , Finite Element Analysis , Tooth, Artificial
16.
Odonto (Säo Bernardo do Campo) ; 19(37): 135-142, jan.-jun.2011. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-789960

ABSTRACT

Avaliar a resistência da união adesiva, pelo ensaio de microtração, de bases para próteses totais confeccionadas com resina acrílica ativada termicamente (Lucitone 550 - Dentsply) a dentes artificiais de resina acrílica (Biotone - Dentsply), submetidos a diferentes condições pós-prensagem e períodos de armazenagem.Metodologia: foram confeccionados 32 conjuntos dente/base de resina acrílica, separados em quatro grupos (n=8) conforme o tempo pós-prensagem até a acrilização (imediatamente após ou 24 h após a prensagem) e período de armazenagem em água destilada (24 horas ou 30 dias, em água destilada à 37°C). Sendo assim, 4 grupos foram formados: G1 (Imediato; -sem armazenagem); G2 (Mediato - sem armazenagem); G3 (Imediato - com armazenagem); e G4 (Mediato - com armazenagem). Os conjuntos dente/base de resina foram seccionados em dois eixos, x e y, com um disco diamantado sob irrigação constante (área adesiva - 1mm2) obtendo-se aproximadamente 96 corpos de prova (cp) por grupo. Imediatamente após o corte, os cp foram fixados em um dispositivo de microtração acoplado a uma máquina de ensaio universal (EMIC-DL-1000, Brasil) e testado com velocidade de 1mm/min. Os dados foram submetidos ao teste Anova e Tukey (=0,05).Resultado: os valores médios (MPa) obtidos foram: G1: 27,82 ±12,68, G2: 29,92 ±13,73, G3 30,09 ±20,48 e G4: 32,51±13,81.Conclusão: as diferentes condições pós-prensagem e períodos de armazenagem não influenciaram na resistência de união adesiva dente/base de resina...


The objective of this study was to compare the tensile bond strengths by the micro tensile test of conventional heat-cured resin denture (Lucitone 550 – DENTSPLY) with acrylic resin denture teeth (Biotone – DENTSPLY), submit in a different polymerization cycle and storage.Methodology: thirty two specimens were fabricated and divided in four groups (n=8): G1 (immediate; without storage); G2 (mediate; without storage); G3 (immediate; with storage); G4 (mediate; with storage). Theses specimens was storage in distilled water until testing and cut in two axis, X and Y, with a diamond disc, getting 12 specimens with ± 1 mm² of adhesive area. The specimens were fixed in a specific device that was fixed in a universal testing machine (EMIC-DL-1000, Brazil) and tested with a cross-speed 1 mm/min.Results: the microtensile bond strengths values was G1 (27,82 ±12,68), G2 (29,92 ±13,73), G3 (30,09 ±20,48) e G4 (32,51±13,81).Conclusion: within the limitations of this study, there no was difference between these groups...


Subject(s)
Humans , Dental Bonding/methods , Acrylic Resins/chemistry , Tooth, Artificial , Materials Testing , Polymerization , Reproducibility of Results , Surface Properties , Tensile Strength , Time Factors
17.
Araçatuba; s.n; 2009. 73 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-563711

ABSTRACT

Demonstração do problema: alterações oclusais sempre ocorrem durante o processamento de próteses totais, entretanto, o deslocamento do dente no sentido ocluso-cervical e sua relação com a profundidade do palato ainda não foi totalmente evidenciada. Objetivos: esse estudo investigou a movimentação dos segundos molares superiores em próteses totais processadas com resina acrílica, com diferentes profundidades de palato e com diferentes materiais de inclusão. Métodos: vinte e oito próteses totais superiores idênticas foram confeccionadas sobre o modelo com palato raso e vinte e oito próteses sobre o modelo com palato profundo. Essas próteses foram divididas em quatro grupos com 14 unidades de acordo com o tipo de palato e o tipo de material de inclusão (gesso ou silicone). Foram demarcados pontos na face distal dos segundos molares e no modelo como referência para a mensuração do deslocamento dos dentes. O deslocamento vertical, horizontal e angular foi verificado através das imagens das próteses com o programa AutoCad em dois momentos: antes da inclusão em mufla e depois da demuflagem (sem a separação do modelo). Os valores foram submetidos ao tratamento estatístico de Kolmogorov- Smirnov e ANOVA com o Tukey e Fisher post hoc test a 5% de significância. Resultados: Os resultados não mostraram diferença estatística significante entre os grupos nos deslocamentos angular (p=0,674) e horizontal (p=0,856). Entretanto, no sentido cervico-oclusal, foi observada diferença entre os grupos (p=0,012) apontando maiores alterações para aqueles cuja inclusão foi realizada com o silicone (E3=0,047 e E2=0,044 cm)em relação ao gesso (E1 = 0,027 e C= 0,026cm). Os grupos com diferentes profundidades de palato não apresentaram diferença estatística significante entre si. Conclusão: esse estudo pôde concluir que o tipo de palato não influenciou na movimentação dos segundos molares, já o método de inclusão influenciou de maneira significativa no deslocamento vertical desses dentes...


Statment of the problem: occlusal changes always occur during the complete dentures, however, the cervical-occlusal displacement of the tooth and its relationship with the plate depth has not yet been well clarified. Purpose: This study investigated the movement of the second molars in complete dentures processed with different palate depths and different materials for inclusion. Methods: Twenty-eight complete maxillary dentures were made on cast with shallow palate and twenty-eight on the cast with deep palate. These grafts were divided into four groups with 14 units according to the type of palate and the type of material for inclusion (gypsum or silicone). Points were marked on the distal face of second molars and in the model for measuring the displacement of the teeth. The vertical displacement, horizontal and angular was verified by the images of the prosthesis with the AutoCad program on two occasions: before inclusion and after deflasking (without the separation of the cast). The values were submitted to statistical Kolmogorov-Smirnov test and ANOVA with Tukey’s and Fisher’s post hoc test at 5% significance. Results: The results showed no statistically significant difference between groups in the angular displacement (p = 0674) and horizontal (p = 0856). However, the cervical-occlusal direction (vertical displacement), difference was observed between the groups (p = 0012) indicating major changes to those whose inclusion was performed with silicone (E3 = 0047 and E2 = 0044cm) on gypsum (E1 = 0027 and C = 0026cm). The groups with different depths of the palate showed no statistically significant difference between them. Conclusion: This study could conclude that the type of palate did not influence the movement of the second molars, as the method of inclusion of a significant influence on the vertical displacement of the teeth. Clinical implications: The knowledge of how the movement of the teeth occurs at different depths of the palate and its...


Subject(s)
Acrylic Resins , Denture, Complete , Tooth Movement Techniques , Palate , Tooth, Artificial
18.
Braz. dent. j ; 20(2): 156-161, 2009. ilus, tab
Article in English | LILACS | ID: lil-524512

ABSTRACT

The aim of this study was to compare the bond strength between acrylic denture base and teeth subjected to 6 surface treatments. Ninety-six specimens were made with poly(methylmethacrylate) teeth bonded to a microwave-polymerized acrylic denture base material. The specimens were distributed into 6 groups (n=16) according to surface treatments: CT - no treatment (control); MN - methylmethacrylate monomer etching; AO - 50-µm-particle aluminum oxide air abrasion; BR - glaze removal with a round bur; ST - surface grinding with an aluminum oxide abrasive stone; group CV - cavity preparation (diatorics). The control and surface-treated groups were subjected to a compressive load at 45º angle to the long axis of the teeth. Data were analyzed by one-way ANOVA, followed by Scheffé's test (p<0.05). Bond strength means and (SD) in kgf for groups were: CT: 18.19 (7.14), MN: 18.34 (5.28), AO: 23.82 (5.40), BR: 23.30 (4.79), ST: 25.39 (7.80) and CV: 17.48 (7.17). There was statistically significant difference (p=0.037997) only between ST and CV. In conclusion, ridge lap surface grinding with an aluminum oxide abrasive stone provided the highest bond strength, though it differed significantly only when compared to diatorics. The other surface treatments provided similar bond between the acrylic denture base and teeth.


Este estudo comparou a resistência de união entre base de prótese e dentes de resina acrílica submetidos a 6 tratamentos de superfície. Noventa e seis espécimes foram feitos com dentes de poli(metilmetacrilato) unidos a uma resina para base de prótese polimerizada por energia de microondas. Os espécimes foram distribuídos em seis grupos (n=16) de acordo com o tratamento de superfície: CT - controle, superfície não alterada; MN - aplicação de monômero de metilmetacrilato; OA - jateamento com partículas de óxido de alumínio de 50 µm; BR - remoção do brilho superficial com broca esférica; PE - asperização com pedra abrasiva de óxido de alumínio e; CV - confecção de cavidade. Os grupos foram submetidos a uma carga compressiva em ângulo de 45 graus com o longo eixo dos dentes. Os resultados foram analisados por meio da ANOVA de um fator, seguido do teste de Scheffé (p<0,05). As médias de resistência (kgf) dos grupos foram: CT: 18,19 (7,14), MN: 18,34 (5,28), OA: 23,82 (5,40), BR: 23,30 (4,79), PE: 25,39 (7,80) e CV: 17,48 (7,17). Houve diferença estatisticamente significante apenas entre os grupos PE e CV (p=0,037997). Pode-se concluir que a asperização da base do dente com pedra abrasiva proporcionou a maior resistência de união, embora com diferença estatisticamente significante apenas em relação à confecção de uma cavidade na base do dente. Os demais tratamentos de superfície proporcionaram valores sem diferenças estatisticamente significativas.


Subject(s)
Denture Bases , Denture Design , Dental Bonding/methods , Tooth, Artificial , Acrylic Resins , Air Abrasion, Dental , Compressive Strength , Dental Etching , Models, Dental , Dental Stress Analysis , Polymethyl Methacrylate , Surface Properties
19.
Araçatuba; s.n; 2009. 73 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-865248

ABSTRACT

Demonstração do problema: alterações oclusais sempre ocorrem durante o processamento de próteses totais, entretanto, o deslocamento do dente no sentido ocluso-cervical e sua relação com a profundidade do palato ainda não foi totalmente evidenciada. Objetivos: esse estudo investigou a movimentação dos segundos molares superiores em próteses totais processadas com resina acrílica, com diferentes profundidades de palato e com diferentes materiais de inclusão. Métodos: vinte e oito próteses totais superiores idênticas foram confeccionadas sobre o modelo com palato raso e vinte e oito próteses sobre o modelo com palato profundo. Essas próteses foram divididas em quatro grupos com 14 unidades de acordo com o tipo de palato e o tipo de material de inclusão (gesso ou silicone). Foram demarcados pontos na face distal dos segundos molares e no modelo como referência para a mensuração do deslocamento dos dentes. O deslocamento vertical, horizontal e angular foi verificado através das imagens das próteses com o programa AutoCad em dois momentos: antes da inclusão em mufla e depois da demuflagem (sem a separação do modelo). Os valores foram submetidos ao tratamento estatístico de Kolmogorov- Smirnov e ANOVA com o Tukey e Fisher post hoc test a 5% de significância. Resultados: Os resultados não mostraram diferença estatística significante entre os grupos nos deslocamentos angular (p=0,674) e horizontal (p=0,856). Entretanto, no sentido cervico-oclusal, foi observada diferença entre os grupos (p=0,012) apontando maiores alterações para aqueles cuja inclusão foi realizada com o silicone (E3=0,047 e E2=0,044 cm)em relação ao gesso (E1 = 0,027 e C= 0,026cm). Os grupos com diferentes profundidades de palato não apresentaram diferença estatística significante entre si. Conclusão: esse estudo pôde concluir que o tipo de palato não influenciou na movimentação dos segundos molares, já o método de inclusão influenciou de maneira significativa no deslocamento vertical desses dentes...


Statment of the problem: occlusal changes always occur during the complete dentures, however, the cervical-occlusal displacement of the tooth and its relationship with the plate depth has not yet been well clarified. Purpose: This study investigated the movement of the second molars in complete dentures processed with different palate depths and different materials for inclusion. Methods: Twenty-eight complete maxillary dentures were made on cast with shallow palate and twenty-eight on the cast with deep palate. These grafts were divided into four groups with 14 units according to the type of palate and the type of material for inclusion (gypsum or silicone). Points were marked on the distal face of second molars and in the model for measuring the displacement of the teeth. The vertical displacement, horizontal and angular was verified by the images of the prosthesis with the AutoCad program on two occasions: before inclusion and after deflasking (without the separation of the cast). The values were submitted to statistical Kolmogorov-Smirnov test and ANOVA with Tukey’s and Fisher’s post hoc test at 5% significance. Results: The results showed no statistically significant difference between groups in the angular displacement (p = 0674) and horizontal (p = 0856). However, the cervical-occlusal direction (vertical displacement), difference was observed between the groups (p = 0012) indicating major changes to those whose inclusion was performed with silicone (E3 = 0047 and E2 = 0044cm) on gypsum (E1 = 0027 and C = 0026cm). The groups with different depths of the palate showed no statistically significant difference between them. Conclusion: This study could conclude that the type of palate did not influence the movement of the second molars, as the method of inclusion of a significant influence on the vertical displacement of the teeth. Clinical implications: The knowledge of how the movement of the teeth occurs at different depths of the palate and its...


Subject(s)
Acrylic Resins , Denture, Complete , Tooth Movement Techniques , Palate , Tooth, Artificial
20.
The Journal of Korean Academy of Prosthodontics ; : 82-90, 2009.
Article in Korean | WPRIM | ID: wpr-44648

ABSTRACT

STATEMENT OF PROBLEM: Recently, as patients'expectation and interest for esthetics are increasing, concerns of esthetic restoration for removable dentures as well as fixed prosthodontics are also increasing. And the color stability of artificial teeth will affect a long term success rate of the denture. But the stain or discoloration of these artificial teeth as well as denture resin has caused esthetic problem. PURPOSE: This study was designed to evaluate the influence on color stability of artificial teeth when soy sauce, red pepper paste and coffee which many Koreans have eaten were applied. MATERIAL AND METHODS: For artificial teeth type (Endura Anterio(R), Physio Duracross(R), Trubyte Biotone(R)) selected for the study, 10 specimens each were soaked into individual beakers of soy sauce, red pepper paste, coffee and distilled water. And L*, a*, b* value were measured for evaluation of the color difference (delta E*) with spectrophotometer on the 1 day, 1 week, 2 weeks, 4 weeks and 8 weeks after immersion. RESULTS: 1. delta E* value of artificial teeth which were soaked in soy sauce and coffee was various according to soaking periods. However there was significant difference between Trubyte Biotone(R) and Physio Duracross(R) in red pepper paste regardless of soaking period (P < .05). 2. Except for 8 weeks of Endura Anterio(R), 4 weeks and 8 weeks of Physio Duracross(R), artificial teeth soaked in red pepper paste regardless of the type had significant difference of _E* value compared with other groups (P < .05). 3. a*, b* value of Endura Anterio(R) and Trubyte Biotone(R) which were soaked in red pepper paste had significant difference compared with the value of other group (P < .05). CONCLUSION: Red pepper paste had the greatest effect on color difference of artificial tooth. Physio Duracross(R) showed relatively less color difference than Trubyte Biotone(R) and Endura Anterio(R). But as delta E* difference were all less than 3.3, these artificial resin teeth seemed appropriate for clinical use.


Subject(s)
Capsicum , Coffee , Dentures , Esthetics , Immersion , Prosthodontics , Soy Foods , Tooth , Tooth, Artificial , Water
SELECTION OF CITATIONS
SEARCH DETAIL